The ATE 12-wireless module is very compact and lightweight. It includes the conditioning for type K thermocouples or 12 extensometry gauges. Data is transmitted using frequency modulation (PCM) wireless. It is battery (3.6V) or 12/24V powered. Data can be recovered in analogue output format or CAN2B or USB3 format or IENA. Applications are multiple (distorsion or temperature measurement on transmission shafts, rotating machinery, in the automotive, aeronautical or industrial sectors).
Request a quotebattery powered, lithium battery powered or 12/24 V powered
maximum temperature -40°C + 125°C (-20°C +85 °C for battery powered) 210 °C bespoke high temperature measurement option
maximum acceleration 1 000G
bandwidth up to 200 ech/s
size: 125X60X40 mm
gain and offset programmable by USB 2 ( soft PC ) or remotely using radio transmission
digital PCM radio transmission
anodised aluminium case
radio receiver output 0-5V , 0-10V analogue and USB 3 (CAN2B,IENA option available)
There is also a bespoke broadband, high temperature (+200°C) line for all specific applications.